Importadora Biodinámica SpA · Scientific equipmentSantiago, Chile · biodynex.clEspañol
BiodynexRequest a quote
BIOBASE chromatography refrigerator — 450-1000 L, 2-8 °C
Refrigerators · Chromatography

BIOBASE chromatography refrigerator

450 and 1000 L refrigerators with a pass-through port for running cables and hoses inside, a heated glass door that prevents condensation, and stated control of 0.1 °C accuracy with ≤2 °C uniformity and ≤3 °C stability.

  • Capacities of 450 and 1000 L
  • Heated glass doors
  • Test port and USB interface
  • Optional RS485, printer and logger
Configurations, certifications, power supply, accessories and availability are confirmed in the quote.
Specifications

Summary datasheet

Capacities450 and 1000 L
Temperature range2-8 °C
Stated accuracy0.1 °C
Stated uniformity≤2 °C
Stated stability≤3 °C
Recovery to 8 °C≤15 min (32 °C ambient)
AlarmsHigh and low temperature, thermostat failure, open door and power failure
DoorsHeated glass, 1 or 2 depending on model
CoolingAir
External dimensions680 × 747 × 1885 mm (BSR-5V450); 1220 × 860 × 1885 mm (BSR-5V1000)
Internal dimensions580 × 613 × 1325 mm (BSR-5V450); 1100 × 684 × 1325 mm (BSR-5V1000)
AvailabilityImport to order / to be confirmed

One shelf on the 450 L and six on the 1000

It is the difference that defines this family and the one that explains its name. The 450 L declares a single shelf: the rest of the volume is left clear, which is what you need when a chromatography system is going inside and not a collection of bottles.

The 1000 L comes with six shelves, so it takes both: equipment down below and material on the shelves. Before choosing, it is worth measuring the equipment that will go inside, because the usable interior of the 450 L is 580 × 613 × 1325 mm and that of the 1000 L, 1100 × 684 × 1325 mm.

The 1000 L opens through two doors

Two electrically heated glass doors, against a single one on the 450 L. With a system connected inside, that matters: you can reach one half without opening the other or exposing the whole volume.

Power draw and times do not scale alike

The 450 L draws 220 W and pulls down to 6 °C in up to 70 minutes with 32 °C ambient. The 1000 L draws 300 W and takes up to 100 minutes. More than twice the capacity costs 36% more power, but half an hour more to reach regime.

Recovery time after opening the door is up to 15 minutes on both.

What both bring alike

Precision of 0.1 °C, uniformity of ±2 °C and stability of ±3 °C. Copper-tube condenser and evaporator with aluminum fins, R290 refrigerant, automatic defrost and casters as standard.

The set of alarms is the complete one —high and low temperature, thermostat failure, open door and power failure with eight hours of backup—, and the test port and the USB port are included. RS485, printer and logger remain optional.